# Milestone 1 — Plan of Record (POR) Decisions captured as they are made. This is the working plan for implementing and UAT-ing Milestone 1. It is the source of truth for scope, order, and dispatch; the spec detail lives in `docs/CAPTURE.md` and `docs/PRODUCT.md`. ## Scope Implement **Milestone 1 — Capture** only (see `AGENTS.md`). Browser-only, inference-free, no backend, no Woo create. Milestones 2–4 are out of scope. ## Method — TDD (non-negotiable) Every card is delivered **test-first** per the `test-driven-development` skill: ``` NO PRODUCTION CODE WITHOUT A FAILING TEST FIRST ``` - **Red-Green-Refactor**, tracer-bullet: one behavior slice at a time (RED→GREEN→REFACTOR), not all-tests-then-all-code. - **Verify RED** (watch it fail for the right reason) and **Verify GREEN** (it passes + full suite stays green) are mandatory before the card is done. - Code written before a failing test is **deleted and redone** — not kept as "reference." - The deterministic core (math + PNG contract) is unit-tested in a browser-runnable JS suite; UI behaviors are tested with Playwright against the fixtures. - A card is not complete until: every new function has a test, each test was seen failing first, the full suite passes with pristine output. ## Card breakdown (implementation order) Each card follows TDD. "Define" = write the failing tests (RED); "Build" = minimal code to pass (GREEN); "Refactor" = clean up keeping green. 1. **Scaffold + Dockerfile + test harness** — SvelteKit project with the browser-only M1 runtime (Web Worker, canvas/OffscreenCanvas, IndexedDB via `idb-keyval`), `frontend/Dockerfile`, and the test harness (JS unit runner + **Playwright** web). - *TDD note:* this card establishes the harness itself (a smoke test that runs and fails, then passes) so every later card has a place to be RED/GREEN. 2. **Deterministic core** — the pure math + PNG-encode functions. - *RED:* unit tests for `scale`, `sqft`, `bdft`, width sampling, 1/8″ stepping, rounding, and the PNG contract (3:4, 8-bit RGBA, 80% fill, ≥1600px floor, undersized→retake). Run on the fixtures' calibration records. - *GREEN/REFACTOR:* implement to pass; core is authoritative and server-less. 3. **Capture + Mask** — Add photo (JPEG; HEIC→"retake as JPEG" notice), green/black key, four knobs, debounced recompute, mask approve. - *RED:* Playwright — load fixture, key sheet, approve; empty-mask blocks approve; HEIC shows the notice. - *GREEN/REFACTOR:* build the Mask state to pass. 4. **Length axis** — min-area bounding rectangle + long-side axis, user rotate, approve. - *RED:* Playwright — rect drawn from the approved mask, axis on long side, rotate, approve. - *GREEN/REFACTOR:* build the axis state. 5. **Measure + PNG** — length/thickness (1/8″), compute sqft/bdft/widths, write the 3:4 inventory PNG. M1 stops here. - *RED:* Playwright — enter L/thickness → Calculate; assert PNG is 3:4 with alpha, and numbers equal the fixture's expected values. - *GREEN/REFACTOR:* build Measure + PNG encode. 6. **M1 UAT** — serve the container per `deploy/README.md` §Milestone 1 UAT; run the full Playwright suite in the container; then the manual phone pass. Record host + URL in `deploy/INVENTORY.md`. ## Deployment (UAT) See `deploy/README.md` §Milestone 1 UAT — deployment POR: one container, host chosen at runtime, LAN-reachable URL, no backend. ## Dev / QA worker dispatch Two local inference endpoints are available as dispatchable workers for test / dev / QA: - **`.202:8081`** — `gemma-4-12B-it-q4_k_m` (12B, Q4) — **completion only, no vision.** Use for text/code tasks: drafting, code review, test-writing help. - **`.202:8082`** — `Qwen3.8-27B-UD-IQ3_XXS` (27B, IQ3) — **completion + multimodal (vision).** This is the **vision worker**: any task that must look at a slab photo (bg-removal tuning, mask/axis calibration review, fixture sanity checks) goes here. Coordinator: Hermes (me) — plans, decomposes, dispatches, verifies, and does work directly when a card is small or judgment-heavy. **Rules:** - **Vision tasks → `.202:8082` only.** - **Never more than one task on an endpoint at a time.** Two concurrent jobs on the same endpoint back up and overheat. Serialize dispatch; one endpoint = one active task. - Both run low-quant (Q4 / IQ3). Fine for dispatch-style assist; deep sustained reasoning is better done by the coordinator directly or on a higher-quant model. ## Test plan (M1) Three layers. The deterministic core is unit-tested; the end-to-end path is Playwright; a real phone is the final UAT gate. ### 1. Unit (deterministic core) — must pass before any UI consumes it - `bdft = sqft × thickness_in`; `sqft = (mask_px / scale²) / 144`; `scale = longest_axis_px / L`. - 1/8 in stepping; rounding (sqft/bdft 2 decimals). - Width sampling every 6 in along the approved axis. - PNG encode contract: 3:4 aspect, 8-bit RGBA, 80% fill, shorter side ≥ 1600px when source allows; undersized source → warn + retake (no upscale). - Mask empty → approve blocked. ### 2. Playwright (automated end-to-end, runs in the UAT container's browser) Walks the 5 states against a **sample photo**: - Add photo → Mask (set sheet + sensitivity) → approve → Length axis → approve → Measure (enter L, thickness) → Calculate. - Assert: PNG rendered, dimensions = 3:4, alpha present; sqft/bdft/widths equal the expected values for that fixture (within tolerance); numbers visible on screen. - HEIC input → "retake as JPEG" notice shown (not a crash). - Device draft: reload → Resume → Continue restores last approved state. ### 3. Manual phone UAT (final gate) On a real phone (iOS Safari / Android Chrome) over the LAN UAT URL: repeat the happy path with one real slab; confirm PNG + numbers on screen. Record host + URL in `deploy/INVENTORY.md`. ## Test fixtures (sample pics) Real slab photos are the fixtures (supplied by Ty from `\\truenas.local\Business\Samples`, SMB user `SMBSVC`). Each is a DJI MIMO top-down JPEG, ~4000×2256, slab on a green/black sheet. `tests/fixtures/`: - **sample_01 … sample_0N.JPG** — a representative handful of real slab photos (pulled on demand from the TrueNAS Samples share; do not bulk-copy the whole folder). - Each fixture gets a **calibration record** in `tests/fixtures/.json`: the slab's true length and thickness (in inches), the sheet color, and the approved mask/axis reference — used to compute the expected `scale`, `sqft`, `bdft`, and sampled widths for assertions. The real photos drive both **bg removal** (green/black key) and **rectangle/axis calibration**. Expected values come from the calibration records, so assertions stay deterministic even on real imagery. **M1 fixture set (agreed, complete for M1):** three black-sheet slabs — one irregular (stress-tests the min-area rectangle/axis), two clean elongated. Green-sheet keying is deferred (not an M1 fixture). A 1 HEIC sample (optional) for the decode-fallback test. ## Open decisions - (none outstanding for M1 as of this plan; new decisions append here)