Windows clock sync (w32time) for latency-gated work
Reusable failure mode. Diagnosed 2026-10-11 on Tony's desktop (physical ASUS box) while building a latency-gated paper harness whose spec voids any candidate whose NTP skew exceeds 250 ms.
Symptom
Anything that gates on the local clock fails: an NTP gate rejects every candidate, timestamps look wrong, and the clock drifts instead of holding. On this box the offset went from ~−1.8 s, to ~+10 ms right after a sync, then slid to −284 ms and kept going (~4–5 ms/min).
Diagnose
sc.exe query w32time # STATE: 1 STOPPED == no time sync at all
w32tm /query /status # Leap Indicator, Stratum, Last Successful Sync, Poll Interval
Then measure the offset independently of w32time (a stdlib NTP query against pool.ntp.org, time.google.com, time.cloudflare.com). Multiple servers agreeing confirms it is a real local-clock error, not one bad source. HTTP Date headers are useless for sub-second work — they are whole-second granularity.
Root causes seen (in order encountered)
- The service was stopped.
w32timenot running ⇒ no sync at all. - Registry writes went to the wrong key path.
MinPollInterval,MaxPollInterval,MaxAllowedPhaseOffset,LocalClockDispersionlive underHKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config— not the service root (…\Services\W32Time).reg addreported success but nothing applied.SpecialPollInterval/NtpServerlive under…\W32Time\TimeProviders\NtpClient. - Default poll is 1024 s, so a bad RTC drifts far between syncs.
MaxAllowedPhaseOffset = 1(s) makes w32time slew, not step — it never nulls a sub-second residual. The clock sat stable but stuck at ~−180 ms.
Fix (all elevated)
set CFG=HKLM\SYSTEM\CurrentControlSet\Services\W32Time\Config
set NTP=HKLM\SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\NtpClient
sc config w32time start= auto
w32tm /config /manualpeerlist:"time.google.com,0x1 time.cloudflare.com,0x1 pool.ntp.org,0x1" /syncfromflags:manual /reliable:no /update
reg add "%CFG%" /v MinPollInterval /t REG_DWORD /d 6 /f REM 64 s
reg add "%CFG%" /v MaxPollInterval /t REG_DWORD /d 10 /f
reg add "%CFG%" /v LocalClockDispersion /t REG_DWORD /d 3 /f
reg add "%CFG%" /v MaxAllowedPhaseOffset /t REG_DWORD /d 0 /f REM force a STEP to null the residual
reg add "%NTP%" /v SpecialPollInterval /t REG_DWORD /d 64 /f REM honoured only with the 0x1 flag
net stop w32time & net start w32time
w32tm /resync /force
Result: −284 ms drifting → ±2 ms stable (held over 150 s across four NTP servers).
Lessons
- A
reg addthat "completed successfully" can be a no-op if the key path is wrong. Verify withw32tm /query /configuration, never with the command's exit code. MaxAllowedPhaseOffset: 0forces a step on every sync — right for nulling a residual; if constant stepping is unwanted, raise it to a small tolerance afterwards.- Post-step,
w32tm /query /statuscan readLeap Indicator: 3 (not synchronized)/Stratum 0while the time is actually correct — trust an independent NTP measurement, not the status flag. Dateheaders (1 s granularity) can never satisfy a sub-second freshness/skew gate; measure freshness from local timestamps instead.- Requires elevation (UAC). A physical box with a bad RTC has no host time-integration to fall back on, unlike a VM.